{"id":38645,"date":"2026-08-19T19:53:49","date_gmt":"2026-08-19T17:53:49","guid":{"rendered":"https:\/\/tsecengineering.shop\/shop\/jlr-bcm-bcmb-lear-mc9s12xet256\/"},"modified":"2026-10-12T12:44:05","modified_gmt":"2026-10-12T10:44:05","slug":"jlr-bcm-bcmb-lear-mc9s12xet256","status":"publish","type":"product","link":"https:\/\/tsecengineering.shop\/en\/shop\/jlr-bcm-bcmb-lear-mc9s12xet256\/","title":{"rendered":"BCM \/ BCMB Lear &#8211; MCU Freescale MC9S12XET256 (JLR)"},"content":{"rendered":"<h4>BCM \/ BCMB JLR MCU MC9S12XET256<\/h4>\n<p>Professional service dedicated to <strong>Jaguar Land Rover BCM \/ BCMB modules equipped with the Freescale MC9S12XET256 (2M53J) microcontroller<\/strong>.<\/p>\n<p>This service allows intervention on the data stored in the module for <strong>Emulated EEPROM Recovery<\/strong> and <strong>Cloning<\/strong> operations.<\/p>\n<h4>Available Operations<\/h4>\n<p>You may select one or more services depending on your requirements.<\/p>\n<p><strong>Emulated EEPROM Recovery<\/strong><\/p>\n<p>Restoration of the emulated memory data of the BCM \/ BCMB module in case of corruption or loss of configuration.<\/p>\n<p>Faults typically associated with data corruption may include:<\/p>\n<ul>\n<li>instrument cluster failing to power on;<\/li>\n<li>inability to start the vehicle;<\/li>\n<li>malfunctions attributable to the loss or corruption of module data.<\/li>\n<\/ul>\n<p>This operation can be requested either as <strong>file processing<\/strong> or as a <strong>full module service<\/strong>.<\/p>\n<p>For file processing, it is necessary to provide the readout of the microcontroller&#8217;s <strong>D-Flash<\/strong>.<\/p>\n<p><strong>Cloning<\/strong><\/p>\n<p>Transfer of the necessary data from the original BCM \/ BCMB module to a compatible target module.<\/p>\n<p><strong>Cloning is available exclusively as a full module service and requires the physical shipment of both the original and the target module.<\/strong><\/p>\n<p>Both modules must be clearly identified as <strong>original<\/strong> and <strong>target<\/strong>.<\/p>\n<p>The target module must be technically compatible with the original unit.<\/p>\n<h4>Service Modes<\/h4>\n<p><strong>File processing<\/strong><\/p>\n<p>This mode is available exclusively for <strong>Emulated EEPROM Recovery<\/strong>.<\/p>\n<p>The customer independently performs the D-Flash readout of the microcontroller and sends the corresponding dump to Tsec Engineering.<\/p>\n<p>The service includes:<\/p>\n<ul>\n<li>integrity check of the received file;<\/li>\n<li>recovery of the Emulated EEPROM data;<\/li>\n<li>processing of the necessary data;<\/li>\n<li>return of the file ready for programming.<\/li>\n<\/ul>\n<p>This mode is fully digital and <strong>does not require the physical shipment of the BCM \/ BCMB module<\/strong>.<\/p>\n<p><strong>Full Module Service<\/strong><\/p>\n<p>The customer physically ships the BCM \/ BCMB module to Tsec Engineering. The laboratory handles the entire process: <\/p>\n<ul>\n<li>module identification;<\/li>\n<li>reading of the required memory;<\/li>\n<li>data verification;<\/li>\n<li>execution of the selected operations;<\/li>\n<li>module programming;<\/li>\n<li>final testing.<\/li>\n<\/ul>\n<p>For Emulated EEPROM Recovery, it is sufficient to send the module to be restored.<\/p>\n<p>For Cloning, <strong>both the original module and the target module<\/strong> must be sent.<\/p>\n<h4>Required Data<\/h4>\n<p>Depending on the selected operation and service mode, the following are required:<\/p>\n<ul>\n<li><strong>Emulated EEPROM Recovery &#8211; File processing:<\/strong> D-Flash dump;<\/li>\n<li><strong>Emulated EEPROM Recovery &#8211; Full module service:<\/strong> BCM \/ BCMB module to be restored;<\/li>\n<li><strong>Cloning:<\/strong> original BCM \/ BCMB module and compatible target module;<\/li>\n<li>any additional information requested by technical support.<\/li>\n<\/ul>\n<h4>Procedure<\/h4>\n<p><strong>File processing<\/strong><\/p>\n<ol>\n<li>Purchase the service by selecting Emulated EEPROM Recovery.<\/li>\n<li>Read the microcontroller&#8217;s D-Flash using a compatible programmer.<\/li>\n<li>Send the file to Tsec Engineering, indicating the order reference.<\/li>\n<li>Wait for technical verification of the received dump.<\/li>\n<li>Receive the recovered Emulated EEPROM file.<\/li>\n<li>Correctly repartition the microcontroller memory when required by the programming procedure.<\/li>\n<li>Program the received file into the BCM \/ BCMB module.<\/li>\n<\/ol>\n<p><strong>Complete module service<\/strong><\/p>\n<ol>\n<li>Purchase the service by selecting the required operations.<\/li>\n<li>Ship the BCM \/ BCMB module to Tsec Engineering.<\/li>\n<li>For Cloning, ship both the original module and the destination module, clearly identified.<\/li>\n<li>Wait for service execution and final inspection.<\/li>\n<li>Receive the processed material at the address specified in the order.<\/li>\n<\/ol>\n<h4>Shipping<\/h4>\n<p>For complete service, shipping of modules to Tsec Engineering must be arranged and paid for by the customer.<\/p>\n<p>Shipping costs calculated at checkout refer <strong>exclusively to the return of processed material<\/strong>.<\/p>\n<h4>Important information<\/h4>\n<p>The product includes exclusively the operations selected during purchase.<\/p>\n<p><strong>The module shown in the images is for illustrative purposes only and is not included in the product.<\/strong><\/p>\n<p>Incomplete, corrupted, or incorrectly acquired dumps may require a new reading.<\/p>\n<p>The service does not correct any hardware defects of the BCM \/ BCMB module.<\/p>\n<p>For complete services, any hardware damage or previous tampering may require additional checks before intervention.<\/p>\n<p>For Cloning, the destination module must be technically compatible with the original module. The presence of the same connector or similar external appearance alone does not guarantee compatibility. <\/p>\n<p>In case of doubt about compatibility, contact technical support <strong>before purchase<\/strong>, providing the Part Number and attaching a legible photograph of the original module label and, in case of cloning, also of the destination module.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Professional service for <strong>BCM \/ BCMB Jaguar Land Rover modules equipped with Freescale MC9S12XET256 (2M53J) MCU<\/strong>.<\/p>\n<p><strong>Emulated EEPROM Recovery<\/strong> and <strong>Cloning<\/strong> operations are available.<\/p>\n<p>Emulated EEPROM Recovery can be requested as <strong>file processing<\/strong> or as <strong>complete module service<\/strong>. <strong>Cloning is available exclusively with physical shipment of modules<\/strong>. <\/p>\n","protected":false},"featured_media":36843,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[928,925],"product_tag":[2214,1072,2213,2141,2078,2158,2215,457,2212,458,1074],"class_list":["post-38645","product","type-product","status-publish","has-post-thumbnail","product_cat-ecu-file-service","product_cat-ecu-programming","product_tag-2m53j","product_tag-bcm","product_tag-bcmb","product_tag-cloning","product_tag-d-flash","product_tag-emulated-eeprom","product_tag-file-recovery","product_tag-jaguar","product_tag-jlr","product_tag-land-rover","product_tag-mc9s12xet256","pa_flt-device-target-mc9s12xet256","pa_flt-operation-cloning","pa_flt-operation-emulated-eeprom-recovery","pa_flt-system-bcm-body-computer","pa_for-jaguar","first","instock","taxable","shipping-taxable","purchasable","product-type-variable","has-default-attributes"],"_links":{"self":[{"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/product\/38645","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/comments?post=38645"}],"version-history":[{"count":1,"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/product\/38645\/revisions"}],"predecessor-version":[{"id":38646,"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/product\/38645\/revisions\/38646"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/media\/36843"}],"wp:attachment":[{"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/media?parent=38645"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/product_brand?post=38645"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/product_cat?post=38645"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tsecengineering.shop\/en\/wp-json\/wp\/v2\/product_tag?post=38645"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}